Zephyr UPS

Mono-conversion technology

Use cases

  • Alarm system

  • Medical systems

  • Video Camera

  • Backed up tranformers

  • Emergency light

  • Emergency backup power supply

  • Auto control system

  • Power system communication

  • Network communication including: data transmission, television signal transmission, etc.

Description

The Zephyr series of IPOWER is a Single Conversion Technology Uninterruptible Power Supply (UPS)

In normal operation, these feed incoming utility AC power to IT equipment. If the AC input supply falls out of predefined limits, the UPS utilizes its inverter to draw current from the battery, and also disconnects the AC input supply to prevent backfeed from the inverter to the utility. The UPS stays on battery power until the AC input returns to normal tolerances or the battery runs out of power, whichever happens first. Two of the most popular single-conversion designs are standby and line-interactive:

  • Standby UPSs allow IT equipment to run off utility power until the UPS detects a  problem, at which point it switches to battery power. Some standby UPS designs incorporate transformers or other devices to provide limited power conditioning as well.
     
  • Line-interactive UPSs regulate input utility voltage up or down as necessary before allowing it to pass through to protected equipment. However, like standby UPSs, they use their battery to guard against frequency abnormalities.

Products

POOIP1701 - Zephyr 1 KVA, 700W, 2 batteries 12V7Ah

  • Model(Zephyr) :
  • Capacity(1) : KVA
  • Power capacity(700) : W
  • Input voltage(145-275) : Vac
  • Input frequency : 48-54Hz,same as AC Hz
  • Overload(Fuse protected) :
  • Output voltage(220 ± 5%) : Vac
  • Output frequency(50 ± 0.5) : Hz
  • Power factor(0.7) :
  • Overload capacity(110% @ 60sec 120% @ 5 sec) :
  • Type of batteries(VRLA "Maintenance free sealed acid lead" batteries) :
  • Number of batteries(2 X 12V7Ah) :
  • Temperature(0°C - 40°C,humidity 20% - 90%) :
  • Dimensions(405 X 145 X 220) : mm

POOIP1702 - Zephyr 2 KVA, 1400W, 4 batteries 12V7Ah

  • Type1(Zephyr) : 2 KVA
  • Type2(Power) : 1400 W
  • Type3(Output Voltage) : 220 ± 5% Vac
  • Type4(Autonomy at full load) : 6-8 for 90% capacity Hrs
  • Type5(Battery type) : Sealed acid lead batteries
  • Type6:(Overload capacity) : 120% @ 5sec
Zephyr 3 KVA, 2100W, 4 batteries 12V9Ah

POOIP1703 - Zephyr 3 KVA, 2100W, 4 batteries 12V9Ah

  • Model(Zephyr) : 3 KVA
  • Power : 2100 W
  • Type3(Output Voltage) : 220 ± 5% Vac
  • Type4(Overload Capaccity) : 120% @ 5sec
  • Type5(Battery Type) : Sealed acid lead batteries
  • Type6:(DC current) : 24 V
  • Type7:(Standard Configuration) : 12V9Ah x 02
  • Type8(Noise level) : ≤40 dB(1m)

Specifications

Description Zephyr 1 KVA Zephyr 2 KVA Zephyr 3 KVA
Capacity (W) 700 1400 2100
Screen Display
LCD
Input Voltage 145 – 275 Vac
Input Frequency 48 – 54Hz (same as Vac)
Overload protection Fuse protected
OUTPUT
Output Voltage 220 Vac ± 5%
Output Frequency 50 ± 0.5 Hz
Power Factor 0.7
Sine-wave Pure
Overload Capacity 110 % @ 60sec
120 % @ 5sec
Overload protection Power off after 20ms
Batteries
Battery Type Maintenance free VRLA (Valve Regulated Lead Acid) batteries
DC Current 24 V 48 V
Standard Configuration 12V 7Ah X 2 units 12V 7Ah X 4 units 12V 9Ah X 4 units
Charging Current 2 - 5A
Recharge Time 6 - 8 hrs for 90 % capacity
Physical
Net Weight (Kg) 23.8 30.2 34.5
Environment
Temperature 0 °C - 40 °C/ Humidity
Noise ≤ 40dB (1m)
Altitude < 1000m
Management
USB & RS232 Optional