Sirocco UPS

High Frequency 3-Phased Online Double Conversion Uninterruptible Power Supplies

Use cases

This series UPS is a kind of three-in & out High Frequency )H.F) Online Double Conversion Uninterruptible Power Supply, it can solve most of the power supply problems, such as blackout, over-voltage, under-voltage, voltage sudden drop, oscillating of decreasing extent, high voltage pulse, voltage fluctuation, surge, inrush current, harmonic distortion (THD), noise interference, frequency fluctuation, etc..

This UPS can be applied to different applications from computer device, automatic equipment, communication system to industrial equipment.

Perks

  • Online Double Conversion

  • Output Transfer Time: 0ms

  • PFC technology

  • Full Digital Control (DSP)

  • Output Power Factor: 0.9

  • Input current harmonic: 3%

  • ECO function

  • Charging/ Rectifier/ Inverter fully digital controlled technology

  • Optomization battery group. Bettery quantity: 16/ 20/ 32 or 60 units (optional)

  • Wide Input Voltage Range: 208 - 478 Vac

  • Wide Input Frequency Range: 46 - 66 Hz

  • DC start

  • Communication port: USB/ RS232/ RS485/ Parallel port/ Dry contact

  • Options: SNMP card/ Relay card

  • LCD & LED, double display

  • Intelligent charging management

  • EPO function

  • Common battery group

  • The output can meet 100% unbalanced load

Description

3Phase In/3Phase Out UPS
It is 3Phase In/3Phase Out high-density UPS system, of which input current is kept in balance without any unbalance problem to occur.


Digital Control
This UPS series is controlled by Digital Signal Processor (DSP); hence increases reliability, performance, self-protection, and self-diagnostics...etc

 

Battery Configuration
10-30 KVA: from 20 blocks to 60 blocks. The battery voltage of this UPS series can be configured at 16 blocks to 30 blocks or above according to your convenience.

40-60 KVA: from 32 blocks to 40 blocks. The battery voltage of this series UPS can be configured at 32 blocks, 34 blocks, 36 blocks, 38 blocks or 120 blocks according to your convenience.
 

Charging Current can be reconfigured
Via setting tool, the user may set the capacity of the batteries as well as reasonable charging current and maximum charging current. Constant voltage mode, constant current mode or floating mode can be switched automatically and smoothly.

 

Intelligent Battery Charging Method
The series UPS adopts advanced three-stage charging method:

  1. Stage: High current constant current charging to guarantee to charge back to 90%.
  2. Stage: Constant Voltage In order to vitalize battery and make sure batteries are fully charged.

  3. Stage: floating mode with this 3-stage charging method, it extends the life of the batteries and guarantees fast charging.
     

LCD Display
With LCD plus LED displays, the user may easily get UPS status and its operational parameters, such as input/ output voltage, frequency & load%, battery % and ambient temperature, etc...
 

Intelligent Monitoring Function
Via optional SNMP Card, you may remotely control and monitor the UPS.
 

EPO Function
The series UPS may be completely shut off when the EPO is pressed. REPO function (Remote EPO) is also available in this series UPS.

 

Products

POOIP1401 - Sirocco 10KVA TT with 20pcs 12V9AH batteries

  • Type1 : Online Double Conversion UPS
  • Type2 : T/ T
  • Voltage : 10Kva V
  • Power factor : 0.9
  • Bypass module : Automatic (in-built)
  • Number of batteries : 18-20 pcs
  • Output transfer time : 0 ms
  • Mode : ECO
  • Battery charge mode : Intelligent
  • Standards : IEC/EN62040-1,IEC/EN60950-1
  • Backup autonomy at full load : 10mins min
  • Noise level : ˂55 Db
  • Paralleling kit : Built-in UPS
  • Features:(surge protection/EMI filter for noise isolation/auto restart, cold start/auto shutdown/automatic frequency synchronization/Self-diagnosis function/surge protection) :

POOIP1402 - Sirocco 20KVA TT with 40pcs 12V9AH batteries

  • Input rated voltage : 380/ 400/ 415 Vac
  • Input voltage range : 208 ~ 478 Vac
  • Input frequency range : 45-55Hz at 50Hz/54-66Hz at 60Hz (auto sensing) Hz
  • Input Power Factor : ≥0.99
  • Current THDI : ≤3%(100% non-linear load) %
  • Generator Input : Supported
  • Output rated voltage : 380/ 400/ 415 Vac
  • Output Power Factor : 0.9
  • Output voltage regulation : ±1 %
  • Output frequency utility mode : ±1%, ±2%, ±4%, ±5%, ±10% of the rated frequency
  • Output frequency battery mode : (50/ 60 ± 0.2%) Hz
  • Crest Factor : 3:1
  • Output THD : ≤2% with linear load
  • Output THD : ≤5% with non linear load
  • Battery voltage(Standard unit: ±120Vdc (2x20pcs 12V9AH); Long run unit Optional Voltage: ±96V/ ± 108V/±120Vdc (16/18/20 pcs optional)) : Refer to Annex_02(a)
  • Battery charge current : Standard unit: 2.7A/ Long run unit: Max.current 10 A
  • Back-up time : Up to 30 minutes of back-up autonomy at full load.
  • Transfer Time : Utility to Battery : 0ms; Utility to bypass: 0 ms
  • AC Mode overload protection(Load≤110%: last 60min,≤125%: last 10min,≤150%: last 1min, >150% change to bypass immediately) :
  • Bat. Mode overload protection(Load≤110%: last 10min, ≤125%: last 1min, ≤150%: last 5S, >150% shut down UPS immediately) :
  • Bypass Mode overload protection : Breaker 40 A
  • Short Circuit overlaod protection : 140 peak A
  • Overheat overload protection(Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately) :
  • Battery Low overlaod protection : Alarm and Switch off
  • Battery overload protection : Advanced Battery Management
  • Noise Suppression : Complies with EN62040-2
  • Audible & Visual alarms : Line Failure, Battery Low, Overload, System Fault
  • Status LED & LCD display(Line Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault) :
  • Reading On the LCD display(Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature) :
  • Technical specs : Refer to Annex_01(a) & (b)
  • Certifications(BS 5750-2:1987 replaced by EN 29002:1987,ISO 9002:1987 in 1994. See attached Annex_03(a)/ (b) & (c) for certifications) :

POOIP1403 - Sirocco 40KVA TT Longue autonomie sans cabine sans batteries (redondance incluse)

  • Type1(Model) : 40 KVA
  • Type2(Capacity) : 36 KW
  • Type3(Phase) : 380/ 400/ 415 Vac Vac
  • Type4(Voltage Range) : 208 ~ 478 Vac Vac
  • Type5(Frequency Range) : 45-55Hz at 50Hz/54-66Hz at 60Hz (auto sensing) Hz
  • Type6(Power factor) : 0.9
  • Type7(Current THDi) : ≤3%(100% nonlinear load) %
  • Type8(Max. voltage: 220Vac: +25%(optional +10%,+15%,+20% ) 230Vac: +20%(optional +10%,+15% ) 240Vac: +15%(optional +10% ) Min. voltage: -45% (optional -10%, -20%, -30%) Frequency protection range: ±10%) : Bypass voltage range
  • Type9(Generator Input) : Support
  • Type10(Output Voltage) : 380/400/415Vac Vac
  • Type11(Output power factor) : 0.9
  • Type12(Voltage Regulation) : ±1% %
  • Type 13(Transfer Time) : Utility to Battery : 0ms; Utility to bypass: 0ms ms

POOIP1404 - Sirocco 30KVA TT with 60pcs 12V9AH batteries

  • Type1 : Online Double Conversion UPS
  • Type2 : T/ T
  • Voltage : 30Kva V
  • Power factor : 0.9
  • Bypass module : Automatic (in-built)
  • Number of batteries(12V9Ah) : 60pcs
  • Output transfer time : 0 ms
  • Mode : ECO
  • Backup autonomy at full load : 15-20 minutes at full load connected to the UPS
  • Noise level : ˂58 Db
  • Standards : IEC/EN62040-1,IEC/EN60950-1
  • Battery charge mode : Intelligent
  • Paralleling kit : Built-in UPS
  • Features:(surge protection/EMI filter for noise isolation/auto restart, cold start/auto shutdown/automatic frequency synchronization/Self-diagnosis function/surge protectio) :
  • Technical specifications : Refer to Annex_01
  • CE & EMC/ LVD Certifications : Refer to Annex_01(a), (b) and (c)
  • ISO Certificate : Refer to Annex_01(d)

POOIP1405 - Sirocco 30KVA TT longue autonomie sans batteries

  • Type1 : Online Double Conversion UPS
  • Type2 : T/ T
  • Voltage : 30Kva
  • Power factor : 0.9
  • Bypass module : Automatic (in-built)
  • Output transfer time : 0 ms
  • Mode : ECO
  • Noise level : ˂58 Db
  • Standards : IEC/EN62040-1,IEC/EN60950-1
  • Battery charge mode : Intelligent
  • Paralleling kit : Built-in UPS
  • Features : (surge protection/EMI filter for noise isolation/a

POOIP1406 - Sirocco 10 KVA TT + SNMP + cable //

POOIP1407 - Sirocco 20 KVA TT + SNMP + cable //

POOIP1408 - Sirocco 30 KVA TT + SNMP + cable //

Cabine batteries sirocco sans batteries (max 80 pcs 7 ou 9 Ah)

SOIIP0301 - Cabine batteries sirocco sans batteries (max 80 pcs 7 ou 9 Ah)

Specifications

Model

SIROCCO 10 KVA

SIROCCO 20 KVA

SIROCCO 30 KVA

SIROCCO 40 KVA

Power

9000(W)

18000(W)

27000(W)

36000(W)

Input

Input Phase

3 Phase 4 Wires and Ground

Input Rated Voltage

380/ 400/ 415 Vac

Input Voltage Range

208 ~ 478 Vac (AUTO-DETECT)

Input Frequency Range

45 - 55 Hz at 50 Hz/ 54 - 66Hz at 60Hz (auto sensing)

Input Power Factor

≥0.99

Bypass Voltage Range

Max voltage: 220 Vac: + 25 % (optional + 10 %, + 15 %, + 20% )

230Vac: +20%(optional +10%,+15% )

240Vac: +15%(optional +10% )

Min voltage: - 45 % (optional – 10 %, - 20 %, - 30 %)

Frequency protection range: ±10%

Current THDI

≤ 3% (100 % nonlinear load)

Generator input

SUPPORTED

Output

Output Phase

3 Phase 4 Wires and Ground

Output Rated Voltage

380/ 400/ 415 Vac

Output Power Factor

0.9

Output Voltage Regulation

±1%

Output Frequency

Utility mode: ±1%, ±2%, ±4%, ±5%, ±10% of the rated frequency(optional)

Battery mode: (50/ 60 ± 0.2%) Hz

CREST Factor

3:1

THD

≤ 2 % with linear load

≤5% with non linear load

Batteries

Battery Voltage

240VDC

480VDC

720VDC

960VDC

Functions

Transfer Time

0 ms

Charging Current

1 à 4 A

Overload Protection AC Mode

Load ≤ 110%: last 60min,≤125%: last 10min,≤150%: last 1min, >150% change to bypass immediately.

Overload Protection BATT Mode

Load ≤ 110%: last 10min, ≤125%: last 1min, ≤150%: last 5S, >150% shut down UPS immediately

verload Protection BYPASS Mode

20 A Breaker

40A Breaker

63A Breaker

80A Breaker

Short Circuit

120A peak

 

164A Peak (adjustable)

Overheat

Line Mode: Switch to Bypass; Backup Mode: Shut down UPS immediately

Low Batteries

Alarm and Switch off

Self Diagnostic

Upon Power On and Software Control

EPO (optional)

Shut down UPS immediately

Battery

Advanced Battery Management

Noise Suppression

Complies with EN62040-2

Audible & Visual Alarms

Line Failure, Battery Low, Overload, System Fault

Status LED & lCD Dispaly

Line Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault

Reading on the LCD

Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature

Commmunication Interface

USB, RS485, Parallel (optional), Coupler dry contact, Intelligent slot, SNMP card (optional), Relay card (optional)

Operating Temperature

0°C~40°C

Storage Temperature

-25°C~55°C

Humidity

0~95% non condensing

Altitude

< 1500m.When>1500m,lower the rated power for use

Safety Conformance

CE,EN/IEC 62040-2,EN/IEC 62040-1-1