IP Master Plus UPS

Check the previous versions
IP Master

Use cases

Low Frequency IP Master Plus (T/T) Online Double Conversion Uninterruptible Power Supply 10-800 KVA

"More resistant and more robust among all Uninterruptible Power Supplies with a built-in GALVANIC ISOLATING Transformer"

Suitable for:

  • Networking environments, such as server rooms, networking equipments, data centers or VOIP, security syatems, medical equipments, banking institutions, manufacturing industries, automation..

  • Reliability and exceptional durability thanks to its Low-Frequency Technology.

  • High level of protection: Totally isolate connected equipment of all electrical disturbances of the electrical network.

  • IGBT rectifier.

  • Anti-harmonic filter "OPTIONAL".

  • Smart battery management.

  • Stand-Alone integrated smart card.

  • Smart networking communication RS232

  • "OPTIONAL" SNMP card.

  • Built-in isolating transformer for a perfect electricity.

  • An output power factor of 0.9.

  • Energy efficiency up to 95%.

 

Perks

Higher energy efficiency up to 95% and with a built-in Galvanic Isolating Transformer

Description

  1. Use recommended number of batteries. At -15% voltage, UPS can guarantee maintaining the specified output voltage at rated load without discharging, but cannot guarantee the float charge voltage for the battery.

  2. IEC62040-3(5.2.2): UPS, at rated load, and input rated voltage 380V, without battery charging current.

  3. IEC62040-3 (5.2.2): UPS, at rated load or overload, and input rated voltage 380V, battery equalizing charging at maximum current.

  4. Set up through the special software at the backend.

  5. Factory setting is 380V, 400V or 415V, which can be set through the software.

  6. Factory setting is 50Hz; 60 Hz can be set through the software.

  7. IEC62040-3.

  8. IEC62040-3, including 0-100-0% load transient. Transient recovery time is 20ms, with an accuracy of 1%.

  9. Factory setting is 0.1 Hz/s; 1Hz/s can be set through the software.

Products

POOIP0316 - IP Master Plus 200 KVA TT

  • Type I(On line double conversion) :
  • By pass(Auto/Manuel) :
  • Type II(T/T) :
  • Transformateur d'isolement(integré) :
  • Type de frequence(basse fréquence) :
  • Voltage(200 KVA) :
  • Puissance(180 KW) :
  • Facteur de puissance(0,9) :
  • Temps de transfert(0ms) :

POOIP1201 - IP Master Plus 20KVA

  • Crest factor : 3:1 (Max)
  • Type 1 : On line Tri phase Low frequency
  • Type II : 20KVA
  • Power : 20Kva/ 18000 W
  • Power factor : >0.97(with filter)
  • Transfer time : 0ms(sector mode <--> battery mode)
  • Nominal frequency : 50/ 60Hz
  • Interface : LCD screen, Led indication, Rs232, Rs485, SNMP
  • Technical specifications : Refer to Annex_01 & 01(a)

POOIP1202 - IP Master Plus 40KVA

  • Type I(On line double conversion) :
  • Type II(T/T) :
  • Transformateur d'isolement(integré) :
  • Type de frequence(basse fréquence) :
  • Voltage(40KVA) :
  • Puissance(36 000W) :
  • Facteur de puissance(0,9) :
  • Temps de transfert(0ms) :
  • Autonomie standard(10 minutes) :
  • By pass(Auto/Manuel) :
  • Nombres de batteries(32) :
  • Types de batteries(12v24ah) :

POOIP1203 - IP Master Plus 80KVA

  • NAPPE HP1050 C+( ) :

POOIP1204 - IP Master plus 10 KVA

POOIP1205 - IP Master plus 30 KVA

POOIP1206 - IP Master plus 60 KVA

  • Technology : Online Double-Conversion
  • Frequency Technology : Low Frequency
  • Galvanic Isolating Transformer : Built-in
  • Nominal capacity : 60 KVA
  • Nominal power capacity : 54000 W
  • Power factor : 0,9
  • Transfer time : 0 ms
  • Bypass : Auto/ Manual
  • Rated AC Input Voltage : 380/ 400/ 415 Vac
  • Input Voltage Range : ±15, (maxim working range : 290Vac~498Vac)
  • Frequency : 50/ 60 Hz
  • Input Frequency Range : 45~65 Hz
  • Power Stepping Time(seconds) : 5~300 S
  • Voltage range for inverter : 320~490 Vdc
  • Recommended number of lead-acid cells : 192 Units
  • Recommended floating charge voltage 2.25V/ cell : 432 Vdc
  • Maximum manual charge voltage 2.40V/ cell : 461 Vdc
  • Battery protective voltage 2.45V/ cell : 471 Vdc
  • Maximum duration for euqlizing charging : 480~1800 min
  • Threshold current for equalizing and floating chrg : 0.001 C~0.025 C A
  • Ripple voltage : ≤1 %
  • Warranty : Three (3) years *conditions applied
  • Dimensions (H X W X D) : 1600 X 880 X 760 mm
  • Safety(IEC60950-1,IEC62040-1-1/ IEC/EN62040-2/ IEC62040-3/ IEC60364-3) :

POOIP1208 - IP Master plus 100 KVA

  • Crest factor(Max) : 3:1
  • Capacity : 100 KVA
  • Capacity : 90 KW
  • Input voltage(380/ 400/ 415 Vac (380 - 25%, 415+20%), (3Ph+N+PE) Vac) :
  • Input frequency : 50/ 60Hz to ±5Hz
  • Input power factor : >0.97 (with filter)
  • Voltage en sortie(±1%) : 380/ 400/ 415 Vac
  • Output frequency : 50/ 60Hz (±0.05%) Hz
  • THDI(Linear mode) : < 2%
  • Efficiency : >92.5%
  • Bypass voltage : 380/ 400/ 415 Vac
  • Bypass frequency(Autodetection) : 50/ 60 Hz
  • Battery voltage : 384 VDC
  • Screen and display : Batteries / Voltage / Charge / Capacity
  • Isolating transformer(Built-in) : Galvanic 100 KVA
  • Bypass : automatic, static and de maintenance
  • Power efficiency : > 2 %

POOIP1209 - IP Master plus 120 KVA

POOIP1210 - IP Master plus 160 KVA

  • Type1(Capacity) : 160 KVA
  • Type2(Power) : 144 KW
  • Type3(Built-In) : Isolating transformer (160) KVA
  • Type4(Input Voltage) : 380/400/415 - (-25%/+20%),(3Ph+N+PE) Vac
  • Type5(Earthing) : Earth leakage current ranges between 3.5 and 1000 mA
  • Type6(Noise reduction) : <60 dB
  • Type7(Has a built-in tank damp circuit for reducing the amplitude of voltage spikes in the electrosurgical output, and a pulse suppression circuit) : Spike suppression
  • Type8(Efficiency) : ˃97 (with filter) %
  • Type9(<3) : THD (Total Harmonic Distortion) %
  • Type10(Power factor) : 0.9
  • Type11(Output Voltage) : 380/400/415Vac(±3%) Vac
  • Type12(Output voltage regulation) : ≥0.5 %
  • Type13(Load regulation response) : <1.5 ms
  • Type14(Noise reduction) : <60dB <65dB dB
  • Type15(Bypass switch) : Static & Manual
  • Type16(RJ45 port to enable to enable telephone line) : Enable
  • Type17(Remote Monitoring) : Enable
  • Type18(Back-up battery autonomy at full load) : 15 min
  • Type19(Output voltage harmonic distortion (THD) on non linear load) : % ≤1
  • Type20(Output frequency) : 50/60Hz(±0.05%) Hz
  • Type21(Three (03) years from date of commissioning.) : Warranty Years

POOIP1211 - IP Master plus 200 KVA

  • Type 1(Capacity) : 200 KVA
  • Type 2(Capacity) : 180 KW
  • Type 3(Input Voltage) : 380/ 400/ 415 Vac (380 - 25%, 415+20%), (3Ph+N+PE) Vac
  • Type 4(Input Frequency) : 50/ 60Hz (±5Hz) Hz
  • Type 5(Input power factor) : >0.97 (avec filtre)
  • Type 6(Output voltage) : 380/ 400/ 415 Vac (±1%) Vac
  • Type 7(Frequency) : 50/ 60Hz (±0.05%) Hz
  • Type 8(Total harmonic distortion) : > 2% (Linear load) %
  • Type 9(Crest factor) : 3:1 (Max.)
  • Type 10(Efficiency) : >92.5% %
  • Type 11(Bypass nominal voltage) : 380/ 400/ 415 Vac Vac
  • Type 12(Bypass nominal frequency) : 50/ 60Hz (auto-sensing)
  • Type 13(Battery voltage) : 380 Vdc 480 Vdc Vdc
  • Type 14(Battery status/ input voltage/ output voltage/ Active load/ Capacity/ ...) : LCD display and alert
  • Type 15(Isolating transformer) : Built-in 200KVA Galvanic Isolating transformer.
  • Type 16(Built-in automatic, static as well as maintenance bypass switch) :
  • Type17(More than 95%) : Energy (yield) efficiency %
  • Type 18(Two (02) years warranty from date of final commissioning & testing. Inclusive of batteries, parts and labour.) : 2 Years.

POOIP1212 - IP Master plus 300 KVA

POOIP1213 - IP Master plus 400 KVA

Specifications

Description

IP MASTER 10 KVA

IP MASTER 20 KVA

IP MASTER 30 KVA

IP MASTER 40 KVA

IP MASTER 60 KVA

IP MASTER 80 KVA

Capacity

9000(W)

18000(W)

27000(W)

36000(W)

54000(w)

72000(w)

Input

Input voltage

380/ 400/ 415Vac (380-25%, 415+20%), (3-phase+N+E)

Operating input voltage range

±15%, (maxim working range : 290Vac~498Vac)

Frequency

50/ 60Hz (±5Hz)

Input frequency range

45~65 Hz

Power stepping time

5~300 S

Voltage range for inverter

320~490 Vdc

Bypass voltage tolerance

Default upper limit 20% default lower limit-40%

Confirmation time for bypass voltage recovery

2S

Output

Output voltage

380/ 400/ 415 Vac (±1%)

Frequency

50/ 60Hz (±5Hz)

Total Harmonic Distortion (THD)

< 3% (linear load)

Crest factor

3:1 (Max)

Efficiency

89% >90% >91% >92%

Bypass

Nominal voltage

380/ 400/ 415

Nominal frequency

50/ 60 Hz

Battery

Battery voltage

384 vdc

SYSTEM FEATURES Long run unit depends on the capacity of external batteries. Estimated remaining time displayed on front LCD

Transfer time

0ms (Sector mode < - - > Battery mode)

Overload

110%/ 60 min, 125%(10mins, 150% 1 min

Interface

LCD, LED indicator, SNMP adaptor, dry relay, RS232, RS485, SNMP card (optional)

Optional

Anti-harmonic filter, SNMP adaptor, LBS cable, battery thermometer, Bypass current sharing indicator

Environment

Operating temperature

0 – 40°C

Stocking temperature

-25°C - 55°C

Humidity

0 – 95% (non condensing)

Altitude

< 1500m

Volume

60dB < 65dB

Dimensions (W x H x D) mm

 

570 X 800 X 1198

Standards

Security

IEC60950-1,IEC62040-1-1 IEC/EN62040-2 IEC62040-3 IP20 standards

EMC

IEC/EN62040-2,IEC6100-4-2,IEC6100-4-3,IEC6100-4-4,IEC6100-4-5, IEC6100-4-6,IEC6100-4-8

Description

IP MASTER 100 KVA

IP MASTER 120 KVA

IP MASTER 160 KVA

IP MASTER 200 KVA

IP MASTER 300 KVA

IP MASTER 400 KVA

Input

Input voltage

380/ 400/ 415Vac (380-25%, 415+20%), (3-phase+N+E)

Operating input voltage range

±15%, (maxim working range : 290Vac~498Vac)

Frequency

50/ 60Hz (±5Hz)

Input frequency range

45~65 Hz

Power stepping time

5~300 S

Voltage range for inverter

320~490 Vdc

Bypass voltage tolerance

Default upper limit 20% default lower limit-40%

Confirmation time for bypass voltage recovery

2S

Output

Output voltage

380/ 400/ 415 Vac (±1%)

Frequency

50/ 60Hz (±5Hz)

(Max) output current

152A

182A

243A

304A

456A

608A

Total Harmonic Distortion (THD)

< 2% (linear load)

Crest factor

3:1 (Max)

Efficiency

>92%

>92%

>92%

>92.5%

>93%

>94%

Bypass

Nominal voltage

380/ 400/ 415

Nominal frequency

50/ 60 Hz (auto sensing)

Battery

Battery voltage

384 vdc

SYSTEM FEATURES Long run unit depends on the capacity of external batteries. Estimated remaining time displayed on front LCD

Transfer time

0ms (Sector mode < - - > Battery mode)

Overload

110%/ 60 min, 125%(10mins, 150% 1 min

Interface

LCD, LED indicator, SNMP adaptor, dry relay, RS232, RS485, SNMP card (optional)

Optional

Anti-harmonic filter, SNMP adaptor, LBS cable, battery thermometer, Bypass current sharing indicator

Environment

Operating temperature

0 – 40°C

Stocking temperature

-25°C - 55°C

Humidity

0 – 95% (non condensing)

Altitude

< 1500m

Volume

60dB < 65dB

Dimensions (W x H x D) mm

 

1160 X 805 X 1600 (6P)

1400 X 945 X 1900 (6P)

1640 X 1040 X 1900 (6P)

 

1520 X 830 X 1600 (12P)

1640 X 1040 X 1900 (12P)

1760 X 1040 X 1900 (12P)

Standards

Security

IEC60950-1,IEC62040-1-1 IEC/EN62040-2 IEC62040-3 IP20 standards

EMC

IEC/EN62040-2,IEC6100-4-2,IEC6100-4-3,IEC6100-4-4,IEC6100-4-5, IEC6100-4-6,IEC6100-4-8